VS G2 & VS Series

Steam Sterilisers are for Centralised Sterile Reprocessing
Sychem’s VS and VS G2 Series, in partnership with Steelco, offer high-capacity steam sterilisers for centralised sterile reprocessing. Our sterilisers are versatile, safe, and use advanced technology, which represents the perfect solutions from the smallest facility to the largest central sterilisation supply department, with a processing capacity of 4 STU up to 18 STU per cycle. Sychem’s series’ devices combine high productivity with cost efficiency, improving CSSD running costs. Leading-edge technologies such as NCG & 4DIR Sensors, respectively the only sensor that can measure the Non-Condensable Gases (NCGs) and quantify them in every steam sterilisation process and the only commercially available instrument that ensures the control of sterilisation conditions by direct measuring the sterilant conditions, available as an option.

A high-quality AISI 316 L squared design chamber minimizes dead space for optimal loading and throughput. The best possible jacket covering ensures fast heating and reduces cycle times and areas of potential condensation. High-quality AISI 316 L steam process circuits guarantee long-term reliability and steam cleanliness. Advance Eco Options guarantees unrivaled levels of efficiency, energy, and water consumption reduction with the lowest operating costs per load, assisting our customers in their goals toward environmental sustainability.

Our solutions are trusted by industry leaders for critical processes in Infection Control & Life Science sectors:

Client 1

Key Features

  • Flexible Solutions

    Five models with vertically sliding doors, with five chamber sizes ranging from 322 to 966 liters / 11.37 to 34.11 cu ft. Five models with horizontal sliding doors, five-chamber sizes, and a book from 530 to 1538 liters / 18.72 to 54.31 cu ft.

  • Process Quality Focus

    A series of advanced process safety and quality features, such as a direct steam injection into gaskets, jacket, and chamber; a high-efficiency heat transfer jacket system or the built-in degassing device.

  • Optimised Process Speed

    The two-stage liquid ring vacuum pump ensures faster processes and perfectly matches the chamber size. Vacuum pump options and Eco options also help to shorten process times.

  • Ergonomics

    Fixed or adjustable transport trolley from 4 up to 12 STU capacity, also on floor loading version.

  • Full Traceability

    Full history cycle traceability, compatible with Steelco Data Pro. Ethernet Port for network communication.

  • 7″ or 10″ User-Friendly HMI

    A sizeable intuitive touchscreen control panel supports operators in every step of their interaction—hands-free cycle programs selection via a barcode scanner.

Discuss The Range

Certifications

  • Steelco VS G2 Series sterilisers comply with the European Regulation for Medical Devices: MDR 2017-745-EU and its revised versions; European Directive for Medical Devices (93/42/EEC and its revised versions); Pressure Equipment Directive (PED 2014/68/EU).
  • Steelco VS SC G2 Series sterilisers comply to the European Regulation for Medical Devices: MDR 2017-745-EU and its revised versions; Pressure Equipment Directive (PED 2014/68/EU).
  • Steelco VS Series sterilisers conform to European Directive for Medical Devices (93/42/EEC and its revised versions); Pressure Equipment Directive (PED 2014/68/EU).
Discuss The Range

Configurations

Model

Width (mm)

HMI

Doors

Chamber Volume (L)

Load Capacity (STUs)

Enquire
VS G2 950 Top of Chamber Vertical Sliding 996 4 – 6 – 8 – 10 – 12
VS SC G2 1250 Side of Chamber Vertical Sliding 9664 – 6 – 8 – 10 – 12
VS H G21660Side of Chamber Horizontal Sliding15386 – 9 – 12 – 15 – 18
VS 31000Side of ChamberVertical Sliding3003
VS 4 1250Side of ChamberVertical Sliding 333 4
VS 6-121100Side of ChamberVertical sliding9106 – 8 – 10 – 12
VS H1860Side of Chamber Horizontal Sliding1344 12 – 15 – 18

More Information

Safety, Design and Strength

The sterilisation chamber and the steam process piping are made of high-quality AISI 316 L stainless steel, guaranteeing long-term reliability and steam cleanliness. Easy to remove and refit CFC-free thermal insulation isolates the acid-proof stainless steel chambers and piping. With the ease of service in mind, most piping is connected using stainless steel tri-clamps, and principal components such as the vacuum pump are installed on sliding rails.

Integral Traceability

VS series of steam sterilisers are compatible with SteelcoData suite software for management and traceability. SteelcoData Live instantly displays and stores your sterilisers’ performance, cycles performed, and consumption. In addition, SteelcoData Pro tracks the localisation and status of your sets and instruments through each stage of reprocessing.

Layout Optimisation Solutions

Steelco is renowned for developing tailored solutions facilitating users in their daily tasks. A comprehensive range of models and the combination of manual to robotised (un)loading systems allows the optimization of layout solutions. In addition, an integrated system planning service based on 3D architectural modelling helps customers define the optimal layout configurations for new or refurbishment projects.

Multiple Loading Option

Steelco’s range includes accessories to improve the efficiency of the CSSD, loading carts, systems for stacking baskets and containers, motorised transfer trolleys with adjustable height, and conveyors and pass-through hatches. The “Easy-Load System” accessories for stackable loads eliminate the need for loading racks and pass-through hatches or windows.

Downloads

Infection Control The Complete Solution

Infection Control The Complete Solution

Download

Steelco VS G2 Series Steam Sterilisers

Steelco VS G2 Series Steam Sterilisers

Download

Thank you for requesting a quote. A member of our team will be in touch shortly.

Request a Quote: VS G2 & VS Series

Company Details

EMERGENCY CALL OUTS

Emergency Breakdown Assistance Available 24/7

If you are experiencing an equipment emergency, don’t hesitate to call us immediately. Our dedicated team is ready to help you around the clock.

Out of Hours

023 8001 3531

During Office Hours

02380 240729